Fall protection system OPTISAFE OSL
Horizontal, freely traversable cable system in accordance with EN 795:2012 type C + E for use with personal protective equipment (PPE). For maintenance, care and repair work on green roofs and gravel roofs.
The cable system is load-bearing and therefore does not interfere with the roof waterproofing or roof structure. This means that there are no weak points in the waterproofing. The proven functionality of the fall protection system is ensured by the ballast of the green roof system solutions or by a gravel structure. It is tested and certified for one person and one rescuer.

On green or gravel-covered flat roofs with 0-5° roof pitch
For fall protection during maintenance, care and repair work
Horizontal cable system in accordance with EN 795:2012 type C + E for securing with personal fall protection equipment (PPE) with Optisafe OSR cable slider on stainless steel cable
Required load: 80 kg/m² dry weight
Product properties
| Material | VA stainless steel |
| Fleece size | 9 m² |
| Required load | 80 kg/ m² dry weight |
| Stainless steel cable | D8 mm |
| Post spacing | max. 8 m |
Area of use
- Horizontal rope system in accordance with EN 795: 2012 Type C + E for securing with personal fall protection equipment (PPE) with Optisafe OSR rope glider on stainless steel cable
- For fall protection during servicing, maintenance and repair work
- On green or gravelled flat roofs with a roof pitch of 0-5°
Specific properties
- Rope system can be driven over freely
- No penetration of the roof waterproofing required
- Optisafe basic element OSG consisting of base plate, Post and safety fleece, completely pre-assembled
- Optisafe cable components OSS consisting of bracket sets, end lock sets, stainless steel cable, intermediate brackets, corner guides and cable gliders (in accordance with installation recommendations)
- Fastening of the Optisafe anchorage eye OSA using self-locking nuts
- Safety fleece UV-stabilized, service life installed min. 100 years
- Fleece cut-out possible after consultation with the manufacturer
Accessories
- Optisafe access protection OSZ
Good to know
- Post distance from warm roof to edge of fall at least 2.50m
- Post distance from inverted roof to edge of fall at least 4.00m
- Required installation space/post 3x3m => 9m²
- Corners must be laid diagonally
- Post height 30 cm + component
- Annual inspection by an expert required